<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>nmr.academy</title>
	<atom:link href="https://nmr.academy/feed/" rel="self" type="application/rss+xml" />
	<link>https://nmr.academy</link>
	<description></description>
	<lastBuildDate>Tue, 09 Apr 2024 10:14:45 +0000</lastBuildDate>
	<language>hu</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5</generator>

<image>
	<url>https://nmr.academy/wp-content/uploads/2024/02/cropped-nmr_favicon-32x32.png</url>
	<title>nmr.academy</title>
	<link>https://nmr.academy</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Quantitative NMR I. &#8211; 30° or 90° degree pulse should be used?</title>
		<link>https://nmr.academy/quantitative-nmr-i-30-or-90-degree-pulse-should-be-used/</link>
		
		<dc:creator><![CDATA[Nemes András]]></dc:creator>
		<pubDate>Wed, 03 Jan 2024 15:27:01 +0000</pubDate>
				<category><![CDATA[Posts]]></category>
		<guid isPermaLink="false">https://nmr.academy/?p=473</guid>

					<description><![CDATA[It is impossible to summarize quantitative NMR in a single blog post. It would be as long as a book. That is why this will deal with only one aspect of quantitative NMR, or qNMR for short. If you are not familiar with the technique, I have written a high-level introduction which is available on [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>It is impossible to summarize quantitative NMR in a single blog post. It would be as long as a book. That is why this will deal with only one aspect of quantitative NMR, or qNMR for short. If you are not familiar with the technique, I have written a high-level introduction which is available on the Emery Pharma website. I suggest you start with that.</p>
<p>In this blog post, I will compare the effect of 30° and 90° excitation pulses on the measurement time of a qNMR spectrum. In fact, instead of 30°, I could use any other angle less than 90° and draw the same conclusion. Tl;dr: 90° works better.</p>
<p>The post (or something similar) is available as a Jupyter Notebook for download. Here you can also play with the parameters (e.g. T<sub>1</sub>, percentage of relaxed nuclei, signal-to-noise of a given peak) and optimize the quantitative NMR measurement according to your needs.</p>
<h2>The spin-lattice relaxation</h2>
<p>The first thing we have to introduce is the famous equation describing spin-lattice relaxation, i.e. the rate at which the longitudinal component of the magnetization vector recovers exponentially towards its thermodynamic equilibrium. The equation is the following:</p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-507" src="https://nmr.academy/wp-content/uploads/2024/01/keplet-1.jpg" alt="" width="1190" height="159" srcset="https://nmr.academy/wp-content/uploads/2024/01/keplet-1.jpg 1190w, https://nmr.academy/wp-content/uploads/2024/01/keplet-1-300x40.jpg 300w, https://nmr.academy/wp-content/uploads/2024/01/keplet-1-1030x138.jpg 1030w, https://nmr.academy/wp-content/uploads/2024/01/keplet-1-768x103.jpg 768w, https://nmr.academy/wp-content/uploads/2024/01/keplet-1-705x94.jpg 705w" sizes="(max-width: 1190px) 100vw, 1190px" /></p>
<p>where,</p>
<ul>
<li>Mz(t) is the net z magnetization t time after the pulse</li>
<li>Mz(eq) is the net z magnetization at thermal equilibrium</li>
<li>Mz(0) is the net z magnetization right after the pulse (t = 0)</li>
<li>t is the time since the pulse in seconds</li>
<li>T<sub>1</sub> is the spin-lattice relaxation time of the nucleus</li>
</ul>
<p>Throughout this post, we will discuss what percentage of the nuclei are relaxed after a given time elapsed after a pulse. Since we are interested in percentages, let&#8217;s take Mz(eq) as 1.<br />
Mz(t) will be in this case between 0 and 1, meaning that multiplying it with 100 will provide the percentages of relaxed spins at time t. With this simplification, the equation will be the following:</p>
<p><img decoding="async" class="alignnone size-full wp-image-508" src="https://nmr.academy/wp-content/uploads/2024/01/keplet-2.jpg" alt="" width="1190" height="142" srcset="https://nmr.academy/wp-content/uploads/2024/01/keplet-2.jpg 1190w, https://nmr.academy/wp-content/uploads/2024/01/keplet-2-300x36.jpg 300w, https://nmr.academy/wp-content/uploads/2024/01/keplet-2-1030x123.jpg 1030w, https://nmr.academy/wp-content/uploads/2024/01/keplet-2-768x92.jpg 768w, https://nmr.academy/wp-content/uploads/2024/01/keplet-2-705x84.jpg 705w" sizes="(max-width: 1190px) 100vw, 1190px" /></p>
<p>To be able to illustrate the relaxation curve, we have to define T<sub>1</sub> and Mz(0). The former has to be determined experimentally by using the inversion recovery pulse sequence. Our example will be tryptophan. The T<sub>1</sub> relaxation times of the protons can be seen in Fig. 1. To see how Mz(0) can be calculated, check the next paragraph.</p>
<p><img decoding="async" class="size-full wp-image-513 aligncenter" src="https://nmr.academy/wp-content/uploads/2024/01/figure-1.jpg" alt="" width="452" height="314" srcset="https://nmr.academy/wp-content/uploads/2024/01/figure-1.jpg 452w, https://nmr.academy/wp-content/uploads/2024/01/figure-1-300x208.jpg 300w" sizes="(max-width: 452px) 100vw, 452px" /></p>
<p style="text-align: center;">Figure 1.: The T<sub>1</sub> relaxation time of tryptophan protons in seconds (400 MHz, 40 °C, in D2O)</p>
<h2>The effect of the pulse angle on the spectrum</h2>
<p>This is pretty simple: The excitation angle determines Mz(0) and Mxy(0), i.e. the signal intensity right after the pulse. The relative intensity (when we take the maximum as 1) can easily be calculated when taking the sine of the excitation angle, while Mz(0) can be calculated by taking the cosine of the angle. Based on this, the results are the following:</p>
<table>
<tbody>
<tr>
<td><span style="font-weight: 400;">Excitation angle</span></td>
<td><span style="font-weight: 400;">30°</span></td>
<td><span style="font-weight: 400;">90°</span></td>
</tr>
<tr>
<td><i><span style="font-weight: 400;">M</span></i><span style="font-weight: 400;">z</span><span style="font-weight: 400;">(0)</span></td>
<td><span style="font-weight: 400;">86.6%</span></td>
<td><span style="font-weight: 400;">0.0%</span></td>
</tr>
<tr>
<td><i><span style="font-weight: 400;">M</span></i><span style="font-weight: 400;">xy</span><span style="font-weight: 400;">(0)</span></td>
<td><span style="font-weight: 400;">50.0%</span></td>
<td><span style="font-weight: 400;">100%</span></td>
</tr>
</tbody>
</table>
<p>Oh, wow. Looks like that in the case of a 30° pulse we already have 86% of the equilibrium z magnetization right after the excitation pulse, while we have half of the achievable intensity. Based on this the 30° excitation angle sounds better, but you will see that due to the exponential nature of the relaxation, it is not that advantageous at all.</p>
<h2>How long should we let the protons relax?</h2>
<p>In most cases to reach a desired signal-to-noise ratio (S2N) in the spectrum, we need to acquire more than one scan. By scan we mean what you can see on Fig. 2.</p>
<p><img loading="lazy" decoding="async" class="size-full wp-image-514 aligncenter" src="https://nmr.academy/wp-content/uploads/2024/01/figure-2.jpg" alt="" width="1056" height="330" srcset="https://nmr.academy/wp-content/uploads/2024/01/figure-2.jpg 1056w, https://nmr.academy/wp-content/uploads/2024/01/figure-2-300x94.jpg 300w, https://nmr.academy/wp-content/uploads/2024/01/figure-2-1030x322.jpg 1030w, https://nmr.academy/wp-content/uploads/2024/01/figure-2-768x240.jpg 768w, https://nmr.academy/wp-content/uploads/2024/01/figure-2-705x220.jpg 705w" sizes="(max-width: 1056px) 100vw, 1056px" /></p>
<p style="text-align: center;">Figure 2.: Pulse “sequence” with one pulse: d1 is the relaxation delay, aq is the acquisition time, i.e. the time where we record the FID.</p>
<p>When you do qNMR, you have to wait enough for the nuclei to relax back (or close) to thermal equilibrium before taking the next scan. Actually, that is not important for all the nuclei, but for the ones, we would like to integrate the peak of. In this case, let’s take the signal of the proton with the longest T<sub>1</sub> which is 6.73 seconds (see Fig. 1.). Let’s imagine that all the T<sub>1</sub> of the internal standard protons are shorter than this one, so this will determine how long we have to let the sample relax. But what does “enough” mean?</p>
<p>The precision of the quantification is up to us, but usually, we would like the error to be less than 1%. To minimize error we usually wait until 99% or 99.9% of the nuclei are relaxed, i.e. Mz(t)/Mz(eq) is 0.999. We can calculate this waiting time by transforming eq. (2) as:</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-509" src="https://nmr.academy/wp-content/uploads/2024/01/keplet-3.jpg" alt="" width="1190" height="109" srcset="https://nmr.academy/wp-content/uploads/2024/01/keplet-3.jpg 1190w, https://nmr.academy/wp-content/uploads/2024/01/keplet-3-300x27.jpg 300w, https://nmr.academy/wp-content/uploads/2024/01/keplet-3-1030x94.jpg 1030w, https://nmr.academy/wp-content/uploads/2024/01/keplet-3-768x70.jpg 768w, https://nmr.academy/wp-content/uploads/2024/01/keplet-3-705x65.jpg 705w" sizes="(max-width: 1190px) 100vw, 1190px" /></p>
<p>In this case, the results are the following for the 30° and 90° excitation pulses:</p>
<table>
<tbody>
<tr>
<td><span style="font-weight: 400;">Excitation angle</span></td>
<td><span style="font-weight: 400;">30°</span></td>
<td><span style="font-weight: 400;">90°</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Time to 99% relaxation</span></td>
<td><span style="font-weight: 400;">17.5 s (2.6</span><span style="font-weight: 400;">*</span><i><span style="font-weight: 400;">T<sub>1</sub></span></i><span style="font-weight: 400;">)</span></td>
<td><span style="font-weight: 400;">31.0 s (4.6</span><span style="font-weight: 400;">*</span><i><span style="font-weight: 400;">T<sub>1</sub></span></i><span style="font-weight: 400;">)</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Time to 99.9% relaxation</span></td>
<td><span style="font-weight: 400;">33.0 s (4.9</span><span style="font-weight: 400;">*</span><i><span style="font-weight: 400;">T<sub>1</sub></span></i><span style="font-weight: 400;">)</span></td>
<td><span style="font-weight: 400;">46.5 s (6.9</span><span style="font-weight: 400;">*</span><i><span style="font-weight: 400;">T<sub>1</sub></span></i><span style="font-weight: 400;">)</span></td>
</tr>
</tbody>
</table>
<p><img loading="lazy" decoding="async" class="size-full wp-image-515 aligncenter" src="https://nmr.academy/wp-content/uploads/2024/01/figure-3.jpg" alt="" width="759" height="548" srcset="https://nmr.academy/wp-content/uploads/2024/01/figure-3.jpg 759w, https://nmr.academy/wp-content/uploads/2024/01/figure-3-300x217.jpg 300w, https://nmr.academy/wp-content/uploads/2024/01/figure-3-705x509.jpg 705w" sizes="(max-width: 759px) 100vw, 759px" />Figure 3.: The spin-lattice relaxítion curve in the case of using 30° and 90° excitation pulses. The dashed vertical lines show the time where 99.9% of the nuclei.</p>
<p>Still, the 30° pulse seems to be superior as we have to wait less for the nuclei to relax.</p>
<h2>How many scans are needed?</h2>
<p>We know how much we have to wait between two pulses. But how many scans do we need? Based on the literature at least a signal-to-noise ratio (S2N) of 250 is required. For the sake of simplicity, let&#8217;s say, that the S2N after one scan with a 90° excitation pulse is 125. And here comes an important property of NMR measurements:</p>
<p>“the signal-to-noise ratio scales as the square root of the number of scans coadded.”</p>
<p>Thus, by using 90° pulses 4 scans are needed to reach the S2N 250, since:</p>
<p style="text-align: center;">250 = 125 * sqrt(4).</p>
<p>But what happens when we use a 30° pulse? Remember, the sine of 30° is 0.5, so In this case the S2N after the first pulse will be only 50% of 125, that is 62.5. We have to solve the equation again:</p>
<p style="text-align: center;">250 = 62.5 * sqrt(16).</p>
<p>In this case, 16 scans are needed to reach the desired S2N. Now the 30° pulse doesn’t seem superior, right?</p>
<p><img loading="lazy" decoding="async" class="size-full wp-image-516 aligncenter" src="https://nmr.academy/wp-content/uploads/2024/01/figure-4.jpg" alt="" width="769" height="592" srcset="https://nmr.academy/wp-content/uploads/2024/01/figure-4.jpg 769w, https://nmr.academy/wp-content/uploads/2024/01/figure-4-300x231.jpg 300w, https://nmr.academy/wp-content/uploads/2024/01/figure-4-705x543.jpg 705w" sizes="(max-width: 769px) 100vw, 769px" /></p>
<p style="text-align: center;">Figure 4.: Signal-to-noise ratio (S2N) vs. the number of scans in the case of using 30° and 90° excitation pulses. The black line indicates the desired S2N, which is 250 in this case.</p>
<h2>Calculating the experiment time</h2>
<p>In this paragraph, we are going to calculate how long the experiment takes. Let’s summarize the parameters we are going to use:</p>
<ul>
<li>T<sub>1</sub> of the slowest relaxing proton whose signal we would like to integrate: 6.73 s</li>
<li>Percentage of the relaxed nuclei: 99.9%</li>
<li>S2N after one 90° pulse: 125</li>
<li>S2N we would like to reach: 250</li>
<li>Excitation angle: 30° and 90°</li>
</ul>
<p>We can calculate the experiment time by multiplying the time we have to wait until 99.9% of the spins are relaxed with the number of scans.</p>
<table>
<tbody>
<tr>
<td><span style="font-weight: 400;">Excitation angle</span></td>
<td><span style="font-weight: 400;">30°</span></td>
<td><span style="font-weight: 400;">90°</span></td>
</tr>
<tr>
<td><i><span style="font-weight: 400;">M</span></i><span style="font-weight: 400;">z</span><span style="font-weight: 400;">(0)</span></td>
<td><span style="font-weight: 400;">86.6%</span></td>
<td><span style="font-weight: 400;">0.0%</span></td>
</tr>
<tr>
<td><i><span style="font-weight: 400;">M</span></i><span style="font-weight: 400;">xy</span><span style="font-weight: 400;">(0)</span></td>
<td><span style="font-weight: 400;">50.0%</span></td>
<td><span style="font-weight: 400;">100%</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Time to 99.9% relaxation</span></td>
<td><span style="font-weight: 400;">33.0 s</span></td>
<td><span style="font-weight: 400;">46.5 s</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">S2N one pulse</span></td>
<td><span style="font-weight: 400;">62.5</span></td>
<td><span style="font-weight: 400;">125</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Scans needed (for S2N 250)</span></td>
<td><span style="font-weight: 400;">16</span></td>
<td><span style="font-weight: 400;">4</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Experiment time</span></td>
<td><span style="font-weight: 400;">8.8 min</span></td>
<td><span style="font-weight: 400;">3.1 min</span></td>
</tr>
</tbody>
</table>
<p>Based on these results, we can draw the conclusion that the use of a 90° excitation pulse is recommended. If you play with the parameters in the Jupyter Notebook, you will see that the ratio of the experiment times changes when you change T<sub>1</sub> or the desired percentage of relaxed nuclei, but in all cases, the 90° pulse will be superior.</p>
<p>However, if you drastically decrease the percentage of relaxed nuclei (for example to 90%) then the 30° pulse can provide shorter experiment times. But in this case, the integration will not be quantitative. More on this in another blog post about the Ernst angle.</p>
<h2>What are the suggested parameters?</h2>
<p>Based on all this, here are the suggested parameters for measuring a quantitative NMR spectrum. I only suggest you optimize your measurements to this level when you would like to quantify the same molecule several times. If it is just a one-time measurement, use a sufficiently long d1 (see Fig. 2.). 60 seconds will usually do it.</p>
<ol>
<li>Measure a proton spectrum with one scan: use a 90° excitation pulse (with the right receiver gain settings).</li>
<li>Calculate the S2N in the case of the peaks you would like to integrate.</li>
<li>Calculate how many scans you need to reach at least S2N 250 (or the quality satisfying your needs): 250 = S2N(measured) * sqrt(x). x will be the number of scans you have to use.</li>
<li>Measure the T<sub>1</sub> of the protons of both the quantifiable molecule and the internal standard using the inversion recovery sequence. Among the protons whose signal you want to integrate, choose the T<sub>1</sub> of the slowest relaxing one (i.e. the longest T<sub>1</sub>).</li>
<li>The delay between two pulses should be as long as 6.9 * T<sub>1</sub>. This delay consists of two parts: the relaxation delay (d1) and the acquisition time (aq). Set the aq to be twice as long as the full decay of the FID. Set d1 as d1 = 6.9 * T<sub>1</sub> &#8211; aq</li>
</ol>
<p>I hope this blog post is useful for you to plan and carry out quantitative NMR measurements. Use my Jupyter notebook to calculate and optimize the parameters of your qNMR experiments.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
